Pelican Wireless
Pelican Wireless GW400-LTE Cellular Gateway
Model GW400-LTE SKU 190130
4G LTE gateway connecting Pelican mesh devices through Pelican AnyWhere cellular service.
- Supply voltage
- 5 V DC input; adapter plugs into a 120 V AC outlet
- Communication protocols
- Pelican mesh for local devices; cellular Internet uplink
- Power sources
- Supplied wall power adapter

Pelican Wireless
Pelican Wireless PEARL Advanced Equipment Controller
Model PEARL SKU 190108
Pelican thermostat accessory for economizer, ventilation, variable-speed fan and modulating equipment control.
- Supply voltage
- 24 V AC, 60 Hz
- Communication protocols
- Three-wire connection to a Pelican thermostat
- Power sources
- Hardwired AC

Pelican Wireless
Pelican Wireless PM5-120/240 Power Control Module
Model PM5-120/240 SKU 190119
Five-relay Pelican power control module for scheduled or demand-linked switching of suitable electrical loads.
- Supply voltage
- 120 V AC or 208–240 V AC per installation guide; correct input terminals required
- Communication protocols
- Pelican mesh through separate low-voltage antenna module
- Power sources
- Line-voltage AC

Pelican Wireless
Pelican Wireless PROBE-T1 Duct Temperature Probe
Model PROBE-T1 SKU 190112
Flange-mounted 10K Type II temperature probe for a compatible thermistor input.

Pelican Wireless
Pelican Wireless PROBE-T2 Vinyl Temperature Probe
Model PROBE-T2 SKU 190113
Vinyl 10K Type II temperature probe for a compatible thermistor input.

Pelican Wireless
Pelican Wireless PROBE-T3 Copper Temperature Probe
Model PROBE-T3 SKU 190114
Copper 10K Type II temperature probe for conductive-surface sensing with a compatible input.

Pelican Wireless
Pelican Wireless PRX1 Door/Window and Contact Sensor
Model PRX1 SKU 190111
Battery-powered wireless input for door/window status or an external occupancy sensor on a Pelican thermostat.
- Communication protocols
- Pelican mesh
- Power sources
- Two AA batteries

Pelican Wireless
Pelican Wireless RT1-DC Battery-Powered Remote Thermostat
Model RT1-DC SKU 190110
Battery-powered Pelican remote temperature sensor and adjustment interface for a compatible thermostat or TCM1 controller.
- Measured variables
- Temperature
- Communication protocols
- Pelican wireless mesh; this battery model does not repeat wireless signals
- Mounting
- Interior wall or electrical box, horizontal orientation

Pelican Wireless
Pelican Wireless TA1 Temperature and Alarm Sensor
Model TA1 SKU 190104
Wired sensor accessory for temperature monitoring, averaging, or a dry-contact input on a compatible Pelican device.
- Communication protocols
- Pelican three-wire R/C/D connection
- Mounting
- Flat surface in a moisture-free location; device is not waterproof
- Power sources
- Hardwired AC

Pelican Wireless
Pelican Wireless TC1 Commercial Thermostat
Model TC1 SKU 190132
Connected commercial thermostat with temperature sensing for Pelican building controls. Requires a Pelican Gateway.
- Supply voltage
- 24 V AC nominal, 60 Hz; operating range 23–30 V AC
- Communication protocols
- Pelican mesh network; not Wi-Fi
- Power sources
- Hardwired AC

Pelican Wireless
Pelican Wireless TC3 Commercial Thermostat with CO₂
Model TC3 SKU 190134
Connected commercial thermostat with temperature and CO₂ sensing for Pelican building controls. Requires a Pelican Gateway.
- Supply voltage
- 24 V AC nominal, 60 Hz; operating range 23–30 V AC
- Communication protocols
- Pelican mesh network; not Wi-Fi
- Power sources
- Hardwired AC

Pelican Wireless
Pelican Wireless TC4 Commercial Thermostat with Humidity and CO₂
Model TC4 SKU 190135
Connected commercial thermostat with temperature, humidity and CO₂ sensing for Pelican building controls. Requires a Pelican Gateway.
- Supply voltage
- 24 V AC nominal, 60 Hz; operating range 23–30 V AC
- Communication protocols
- Pelican mesh network; not Wi-Fi
- Power sources
- Hardwired AC

Pelican Wireless
Pelican Wireless WR400 Wireless Repeater
Model WR400 SKU 190105
Plug-in repeater that extends an existing 2.4 GHz Pelican mesh network between devices or buildings.
- Supply voltage
- 5 V DC at repeater; supplied 115 V AC adapter
- Communication protocols
- Pelican mesh; no Ethernet connection required
- Power sources
- Supplied AC power adapter

Pelican Wireless
Pelican Wireless Z8 Zone Coordinator
Model Z8 SKU 190115
Central HVAC zone coordinator for up to eight Pelican zone-thermostat demands, with equipment outputs and duct static-pressure control.
- Supply voltage
- 24 V AC nominal, 60 Hz; operating range 23–30 V AC
- Heating and cooling stages
- Up to three heating and three cooling stages; sequence and equipment configuration must be verified
- Communication protocols
- Pelican mesh network; not Wi-Fi
Selection guidance & equipment requirements
Commercial thermostat selection begins with the controlled equipment and the intended sequence of operation. Some installations use a standalone control; others depend on gateways, equipment controllers, sensors, or a larger building-control network.
Review the system, not only the wall control
Document equipment model numbers, voltage, stages, terminal assignments, accessories, network components, and the site's operational goals. Compare those details with current manufacturer documentation and the project design.
For help organizing a project review, contact sales@coldaircentral.com. Site information is educational and does not replace engineering approval or qualified installation work.