White-Rodgers · Standalone

White-Rodgers 1F95EZ-0671 Blue Easy Reader Thermostat

Easy Reader thermostat with selectable 7-day or non-programmable operation for conventional, multistage and heat-pump systems.

Legacy model

White-Rodgers 1F95EZ-0671

White-Rodgers 1F95EZ-0671

Will this work with my system?

Match your equipment to these requirements before ordering.

Works with

  • Conventional gas, oil or electric systems up to 2H/2C
  • One- or two-compressor-stage heat pumps with up to two auxiliary/emergency heat stages
  • Documented two- or three-wire hydronic zone and millivolt applications

System requirements

  • NEC Class II control wiring; do not connect line-voltage heating circuits.
  • Select SS1, MS2, HP1 or HP2 to match the equipment; configure gas/electric fan operation and dual-fuel logic when applicable.

Check before you buy

  1. Compare the installed equipment voltage, stage count and terminal functions with the installation manual before selecting this model.
  2. Count compressor stages separately from auxiliary stages; the 4H/2C maximum includes auxiliary heat.
  3. For two-transformer conventional systems, compare the equipment with the separate-transformer wiring diagram.
Manufacturer documentation (1)

Use these documents to compare your exact model and configuration.

Overview

Easy Reader thermostat with selectable 7-day or non-programmable operation for conventional, multistage and heat-pump systems.

Choose non-programmable operation or a separate schedule for each day, with two or four periods. Installer settings provide heating and cooling setpoint limits. The manual covers conventional single- and multistage systems, heat pumps, and three-wire zone valves; each uses a different wiring configuration.

Selection and installation

Use the linked manufacturer documents to compare the exact model, equipment configuration and installation requirements before ordering.

Product details

SKU
907756
Model / MPN
1F95EZ-0671
Condition
New
Lifecycle
Legacy

Specifications

Power sources
Two AA alkaline batteries, with power-stealing assist; optional 20–30 VAC hardwired power
Stage modes
Conventional: up to 2H/2C; single-compressor heat pump: up to 3H/1C; two-stage heat pump: up to 4H/2C, including up to two auxiliary/emergency heat stages
Scheduling modes
7-day or non-programmable
Schedule periods per day
2 or 4 in programmable mode
Setpoint range
45–99 °F
Setpoint limits
Heating maximum adjustable 62–98 °F (99 °F default); cooling minimum adjustable 46–82 °F (45 °F default)
Contact ratings
1.5 A per terminal; 2.5 A combined maximum
Operating temperature
32–105 °F
Operating humidity
90% RH maximum, non-condensing
Dual transformer support
Conventional systems supported with RH/RC jumper removed, per diagram
Millivolt support
Documented for conventional systems
Dual fuel support
Selectable logic-based heat-pump/gas or oil auxiliary operation
System modes
Heat; A/C; Off; auxiliary heat in heat-pump configuration
Dimensions
4-3/16 in H × 6-1/2 in W × 1-5/8 in D

Documents & downloads