Honeywell Home · Standalone

T6 Pro TH6210U2001 Programmable Thermostat

UWP-mounted thermostat with seven-day, 5-1-1-day, 5-2-day or non-programmable operation.

T6 Pro TH6210U2001 Programmable Thermostat

T6 Pro TH6210U2001 Programmable Thermostat

Will this work with my system?

Match your equipment to these requirements before ordering.

Works with

  • Staging: Heat pump: 2 heat / 1 cool; Conventional: 1 heat / 1 cool

System requirements

  • Power: Battery or 24 Vac hardwired
  • Electrical load limits: Control circuits: 20–30 Vac

Limitations & exclusions

  • C7089U outdoor and C7189U indoor sensor options are not supported on TH6210U.

Check before you buy

  1. Match the full TH6210U2001 model number and hardware revision to the manufacturer's equipment manual and accessory list.
  2. Compare the equipment terminals, control voltage and required operating sequence with the model-specific installation diagrams.
Manufacturer documentation (2)

Use these documents to compare your exact model and configuration.

Overview

The TH6210U2001 provides push-button temperature and schedule control using the UWP wall mounting system. Select the schedule and equipment type during setup. Unlike higher T6 Pro variants, TH6210U2001 does not support the C7089U outdoor or C7189U indoor sensor options listed in the family submittal.

Selection and installation

Use the linked manufacturer documentation for the exact equipment configuration, wiring and commissioning requirements. Accessories and controls must be matched by model and electrical characteristics.

Product details

Manufacturer
Resideo
SKU
367408
Model / MPN
TH6210U2001
Condition
New
Lifecycle
Current

Specifications

Stage modes
Heat pump: 2 heat / 1 cool; Conventional: 1 heat / 1 cool
Power sources
Battery or 24 Vac hardwired
Contact ratings
Control circuits: 20–30 Vac
Scheduling modes
7-day, 5-1-1-day, 5-2-day or non-programmable
Changeover modes
Automatic or manual
Keypad lockout
Partial/full options; menu enablement differs by hardware series
Setpoint limits
Minimum cool and maximum heat limits, configured by installer
Dual transformer support
Supported for documented conventional 1H/1C wiring
Remote sensor support
C7089U and C7189U options not supported on TH6210U