White-Rodgers · Sensor

White-Rodgers F145-1328 Indoor Remote Sensor

Wired indoor temperature sensor for manufacturer-listed White-Rodgers remote-sensing thermostats, with a maximum 300 ft thermostat-to-sensor run.

Legacy model

White-Rodgers F145-1328

White-Rodgers F145-1328

Will this work with my system?

Match your equipment to these requirements before ordering.

Works with

  • Listed single-stage hosts: 1F90-371, 1F96-344, 1F97-1277, 1F97-371 and 1F97-391
  • Listed staging hosts: 1F93-380, 1F94-371, 1F95-1277, 1F95-371, 1F95-377 and 1F95-391

System requirements

  • Use the host-specific sensor count and configuration in the manual’s page 6 chart.
  • Maximum sensor-to-thermostat distance: 300 ft. Recommended cable: 18 or 20 AWG, three-conductor shielded.
  • Route sensor wiring separately from thermostat/power wiring and enable remote sensing as instructed for the host.

Limitations & exclusions

  • Systems with power interruptions as part of normal operation
  • Outdoor sensing: this is the indoor F145-1328, not the F145-1378 outdoor model.

Check before you buy

  1. Match the complete host thermostat model to the page 6 table, including onboard-sensor and averaging restrictions.
  2. Compare the installation distance and cable routing with the 300 ft limit and shielding instructions.
Manufacturer documentation (1)

Use these documents to compare your exact model and configuration.

Overview

Wired indoor temperature sensor for manufacturer-listed White-Rodgers remote-sensing thermostats, with a maximum 300 ft thermostat-to-sensor run.

The F145-1328 moves indoor temperature sensing to a suitable room location. Supported sensor counts and averaging depend on the host: some models disable the onboard sensor, while selected staging models allow up to three remote indoor sensors. The manual’s per-model chart is the selection reference.

Selection and installation

Use the linked manufacturer documents to compare the exact model, equipment configuration and installation requirements before ordering.

Product details

SKU
907901
Model / MPN
F145-1328
Condition
New
Lifecycle
Legacy

Specifications

Measurement channels
Indoor temperature range: 40–99 °F, subject to the host thermostat range
Operating humidity
0–90% RH, non-condensing
Electrical connections
Three conductors; +, S and − sensor terminals
Dimensions
2-1/8 × 3-1/2 × 3/4 in (manufacturer-listed order)
Color
Classic White
Mounting methods
Indoor partition wall, approximately 5 ft above the floor